Some important Steps for Non Combo configuration
For this link we changed the slots of ISM8 cards from from slto3 and Slot 5 to Slot 4 and Slot 6
As at this link we was receiving Multiple Alarms of BD status Alarms and Bus_ERR Alarms
For these Alarms we first Change Hardware but issue was not fixed then we changed chassis of RTN950A But facing same issue at this link and receiving these alarms again and again BD status and Bus_ERR Alarms.
For these Alarms then i changed Slots from 3 and 5 to Slot 2 and 4.
First Step Adding 2 ISM8 cards at Slot 2 and 4 and MODU at slot 23
2 Then i Click on IF Conflux Port Management for Sharing MODU
3 Creating 2 CA 3 and 4 In CA We added all Parameters e.g. Frequency Tx Power Modulation Scheme Band width
4 Creating XPIC Between 4-ISM8-1(RTNIF-1) and 6-ISM8-1(RTNIF-1)
& 4-ISM8-2(RTNIF-2) and 6-ISM8-2(RTNIF-2)
5 Creating EPLA in Which this Card Main Card was 4-ISM8 Main Port 4-ISM8-1(RTNIF-1)
Slave Ports was
4-ISM8-2(RTNIF-2)
6-ISM8-1(RTNIF-1)
6-ISM8-2(RTNIF-2)
6 Adding VLANs at Port 4-ISM8-1(RTNIF-1)
Link was up at these steps but MAC Address was not Received
For this We Started Troubles Shooting according to Alarms which was active
MW CFG Mismatch Alarms and PLA CFG Mismatch Alarms
For MW CFG Mismatch Alarms we Check All Parameters that at Far End & Near END Parameters are same or not.
For PLA CFG Mismatch Alarms i Checked all the Steps and Found WTR status and CC Status was disabled as I Enable these Ports Mac Received.