Beninca brainy control unit for BoB50/BoB50ME Swing Door Opener.
Beninca brainy control unit wiring Connections.
Connection of Openers.
Motor 1, connection of motor 1 are three terminals.
Terminal four and six for Open and closed start.
Terminal five are common for terminals four and six.
Connect the motor one to control.
Motor 2, connection of motor 2 are three terminals.
Terminal seven and nine for Open and closed start.
Terminal eight are common for terminals seven and nine.
Connect the motor two to control.
Mostly in Beninca openers the capacitor are connected inside the motors.
Motors Encoder Connection.
Here are the motor one and motor two connections from the control section of encoder.
( draw a line control to motor)
Connection of lights.
The terminal ten and eleven for flashlight.
Here the control power supply for flashlight are 230 volt a,c.
Connect the lights to control.
Terminal 12 and terminal 13 are open contact for courtesy light,timer etc.
The activation time is regulated by parameter T,L,S.
Antenna connection.
Terminal 36 are main antenna terminal.
Where solid wire will direct connect here.
Terminal 35 is common wire for terminal 36.
Connection of Photo Sensor.
In this control board have two terminal is used for different safety.
Terminal 33 are closed safety.
when door closing in front of sensor any object come the will stop and reopen.
This terminal will work only closing.
Terminal 32 also one type of safety which work both open and closed safety.
Here now we connect only terminal 32 for closing safety.
If you don’t want any safety just jumper the terminal with common terminal.
Here for sensor Terminal 27 are common for terminal 33 and 32 in control board.
Connection of pushbutton.
Terminal 28,29,30 and 31 are open contact for pushbutton.
Terminal 28 is step by step terminal for open,stop and close by pressing button one time.
And the common are 26 or 27. Any you can you used no problem.
Terminal 29 is pedestrian terminal.
Use for people go or come.
Terminal 30 is only for opening the gate used. This terminal just open the gate by pressing the button.
Not closed not stop just open the gates.
Terminal 31 will work same but just closed.
Connection of jumper.
The jumpers are only for n,c. Contact .
There may jumper let see the marking terminals.