CAUTION ⚠️⚠️⚠️⚠️⚠️!!!!!!
UNPLUG THE ANY APPLIANCES FROM THE SOCKETS WHEN YOU REPAIR OR TEST IT.
BEFORE YOU TEST THE MICROWAVE OVEN PLEASE DISCHARGE THE CAPACITOR!!!!!
test both primary terminals and you should get reading or continuity if not then it's faulty.
test both the terminals that connect to magnetron both and you must get reading or continuity if not then it's faulty and double check if the wires are not broken.
test the high voltage fuse terminal with the transformer body but firstly you should scratch the body so you can have proper reading.
and one of your multimeter probe must be one the terminals and test all of them so you can see if it's not burned inside, you should not get any reading.
thank you