how to connection of dc shunt motor | how to diagram dc shunt motor | dc shunt motor circuit diagram | shorts #shortsvideo #viral #trending #youtubeshorts #tips #basicelectrical
queries solved__________________
how to dc shunt motor connection,
connection of dc shunt motor,
dc shunt motor ke connection,
dc shunt motor connection,
dc shunt motor terminal connection,
dc shunt motor wiring,
shunt motor connection,
shunt dc motor connection,
how to connect dc shunt motor
dc 3 point star with shunt motor connection
3 point starter ke saath shunt motor ki wiring kaise karte he
how to connection diagram of dc motor
shunt motor armature winding connection
shunt motor shunt field winding connection
dc motor ki wiring
circuit diagram of dc shunt motor
how to diagram of dc shunt motor with 3 point starter
3 point starter dc motor animation,
3 point starter terminal name animation,
3 point starter connection
animated diagram of dc shunt motor
#A DC shunt motor is a type of electric motor that operates on direct current and has a shunt field winding that is connected in parallel with the armature winding. The shunt field winding allows the motor to maintain a relatively constant speed under varying loads.
DC Shunt Motor Starter.######
A 3-point starter is a type of motor starter used with DC motors that provides a means of controlling the current and voltage supplied to the motor during starting. It consists of three terminals or points: the line, the field, and the armature. The line terminal is connected to the power source, the field terminal is connected to the shunt field winding, and the armature terminal is connected to the armature winding.
The operation of a DC shunt motor with a 3-point starter involves the following steps:####
The 3-point starter is set to the off position.
The motor is connected to the power source through the line terminal.
The shunt field winding is connected to the power source through the field terminal.
The armature winding is disconnected from the circuit at this point.
The 3-point starter is moved to the first position, which connects the armature winding to the circuit through a resistance. This allows the motor to start with a reduced voltage and current, preventing excessive starting torque and current draw.
As the motor gains speed and the armature current decreases, the 3-point starter is gradually moved to the second and third positions, which reduce the resistance in the armature circuit and increase the voltage and current supplied to the motor.
The motor continues to run at a constant speed under varying loads due to the shunt field winding's ability to maintain a relatively constant magnetic field strength.
Overall, a DC shunt motor with a 3-point starter provides an efficient and effective means of controlling the starting current and voltage of the motor, allowing it to operate smoothly and reliably under varying loads.