Hydraulic Coupling Repair Made Simple
For more videos, visit [ Ссылка ].
Transcript:
The Holmbury Roflex couplings should provide years of reliable service in the most demanding applications when used properly. Over time though, the internal parts may wear due to dirty oil passing through the coupling, or other factors. There’s no need to worry though, Holmbury offers repair kits for each size coupling that allows you to completely rebuild the internal parts of the couplings, and the process is very simple.
Utilizing the Repair Took Kit, consisting of a T-wrench, calibration disk and staking tool, which are all sized for the particular coupling size being repaired, along with the appropriate Repair Kit, consisting of a poppet, spring and retainer for each coupling half as well as the seals for the Probe half, you have all the components necessary to fully rebuild the couplings.
It is imperative that you only rebuild one coupling half at a time, as you need a completely assembled mating coupling to ensure proper spacing of the parts. I’ve already removed the internal components from the cutaway model as you can see. It is recommended that you thoroughly flush the coupling with mineral spirits or a similar type solvent to remove any loose debris, being careful to allow adequate ventilation and observe proper safety precautions.
Insert the calibration disk into the half you are repairing, and screw the Probe and Sleeve together until the disk is fixed. Insert the new poppet, spring and threaded collet into the half you are repairing and tighten with the T-wrench until the spring is fully compressed, then turn back counterclockwise 1/8 of a turn. At this point, you would set the still assembled coupling upright on a flat surface and insert the staking tool through the port of the newly reassembled half and into the slots of the collet, striking the tool firmly with a hammer to sufficiently distort the thread of the collet so it will not loosen when subjected to the severe hydraulic pulsations these couplings are designed to withstand. Unscrew the coupling halves and remove the calibration disk. If repairing the Probe half, insert the o-ring first, and then the back-up ring into the groove. Now you can repair the other half using the same procedure, and when completed you’ll have a set of couplings that should give you many more years of productive service.
Ещё видео!