This is a video on how to trouble-shoot a Semi Cup Sealer Machine . The trouble-shoot is regarding a heat plate that is NOT coming down on the machine. You will need to remove the screws on the back of the machine to expose the unit . More than likely, the wire on top has a LOOSE or DISCONNECTED wire that is inhibiting connection to the machine to lower the heat plate. Reconnect, glue, or screw back the wire into the metal outlet. This will more than likely resolve the issue .
This video also helps you DETECT where the sensor is LOCATED on the machine . The sensor is the 3x colored wire located at the bottom of the machine . This is if you need to replace the sensor on the machine.