Product Introduction
The isolated RS485 repeater is a high-performance industrial-grade RS485 signal amplifier and extender. The product can automatically sense the data flow direction and communication baud rate, without any control or handshake signals, ensuring transparent data transmission. The power supply and communication signal of the equipment are completely isolated, and measures such as surge protection and electrostatic protection are provided. It has the characteristics of long transmission distance, high speed, stable and reliable performance. Widely used in attendance machines, IC card toll systems, automatic control, access control systems, parking lots, canteen food sales systems, road toll systems.
Features
1. Industrial design, complete communication isolation, stable and reliable performance, adaptive baud rate 100-115200Kbps;
2. Built-in high-quality DC/DC isolation power module to realize electrical isolation between ports;
3. Support multi-machine communication, up to 128 nodes can be connected, and the longest transmission distance is 1500 meters;
4. Data flow automatic control technology, automatically distinguish and control the direction of data transmission;
5. Multiple protection measures: ESD protection of plus or minus 15KV, 600W dual-channel TVS protection and 2.5KV communication isolation;
6. The power supply has a wide range of 8-25VDC, and has anti-reverse connection protection;
7. Support standard 35 guide rail installation;
Electrical parameters
1 Working voltage 8-25V (DC 9V 12V 24V)
2 Working current: 12-15MA
3 3000V photoelectric isolation
4 load capacity 1-128 nodes
5 Communication distance 0-1500 meters
6 Adaptive baud rate 100-115200BPS, adaptive parity (NONE ODD EVEN)
7 Size: 100*53*32
8 Weight: 63 grams
RS485 Bus Isolation Protector
Working voltage DC 12V/24V
3000V photoelectric isolation
ESD protectio 15KV
Load capacity 1-128 nodes
Adaptive BaudRate(100-150K)
Adaptive DataBit/Parity/StopBit
Notes on RS485 Wiring
1. The RS485 communication line must use a shielded twisted pair, and it is best to use multiple strands for backup. It is recommended that the total length should not exceed 1500 meters.
2. The wiring should be kept away from high-voltage wires as far as possible, and should not be paralleled with the power wires, let alone bundled together.
3. The RS485 bus must be a hand-in-hand bus structure, and resolutely put an end to star connection and fork connection.
4. If there are more than 30 controllers or the line length is longer than 500 meters, it is recommended to use RS485 repeaters.
5. AC powered equipment and chassis must be truly grounded and well grounded.
6. Connect the GND grounds of all RS485 devices with shielded wires.
Communication using RS-485 bus wire selection requirements:
Use 2-core shielded twisted pair
Copper, wire diameter 0.5 ~ 0.75 square millimeters,
Impedance 3888 ohms/km,
Capacitive reactance 30-50 nanofarads/km,
2-core shielded twisted-pair cable with a twist distance of 20mm (if the cable distance does not exceed 500 meters, the standard of the cable can be appropriately lowered, but it must be a twisted-pair cable)