This Video is a brief Illustrating how Building Vibration Measurements are made according to DIN4150-3. This is a Standard used to help ensure the compliance for Vibration in Buildings specifically effects on structures. This is commonly used for vibration monitoring during construction and Blasting. The Measurement of long term vibration as well as transient impulses are shown. Damage to is described as any permanent consequence of an action that reduces the serviceability of a structure or one of its components. By measuring peak vibration velocity, vi, max, maximum absolute value of the signal v(t) in the direction of measurement i (i = x, y, z) and categorizing them in the severity plot for 3 boundary conditions in real-time allows for immediate action.